Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R
    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R

    Pair of gloves radio attenuator UNIRAY size 8.0 disposable/Box 5 pair Unleaded-powder free-sterile R

    Lead equivalency mm
    Coating
    Size
    Colors
    Length mm
    Width mm
    Types of cuts
    Sterile
    Generate PDF
     
    Sterile single-use radio attenuating gloves size 8.0

    Pair of sterile single-use radio-attenuating gloves intended for hand protection during surgery under ionizing radiation.

    Thin and ergonomic, these gloves ensure perfect dexterity during X-ray procedures as well as excellent grip of the instruments used in functional explorations.

    Each pair of gloves comes in a sterile pouch.

    Composed of low-protein natural rubber, these gloves ensure very good hand hygiene and are guaranteed lead-free.

    These gloves should only be used in scattered radiation. Under no circumstances should they be used in direct X-rays.

    Technical performance:
    ? Nominal lead equivalence 60kV - 120kV: 0.039mm
    ? An optimal combination of high attenuation and tactile sensitivity
    - 63.1% attenuation at 60kVp / HVL 2.5mm Al
    - 54.4% attenuation at 80kVp / HVL 2.5mm Al
    - 47.4% attenuation at 100kVp / HVL 2.5mm Al
    - 42.0% attenuation at 120kVp / HVL 2.5mm Al

    Technical characteristics :
    ? Size: 8.0
    ? Sterile R
    ? Lead-free and non-toxic
    ? Powder-free
    ? Contains natural rubber
    ? Ecological

    Standards and references:
    ? CE according to standard EN 61331-1:2014
    ? CE PPE 2016/425
    ? CE 93/42/CEE
    ? Test standards: EN 420:2003, EN 374:2003, EN 388:2016, EN 421:2010, EN 455:2000, EN ISO 10993
    Lead equivalence mm
    0,039
    Material
    Caoutchouc naturel
    Coating
    Caoutchouc naturel
    Colors
    Sable
    Size
    8
    Cut type
    Mixte
    Length mm
    290
    Width mm
    101
    Net weight kg
    0,65
    Packing
    29x17x6cm
    Gross weight kg
    0,81
    Interventional procedure
    Vasculaire
    Sterile
    Stérile R
    CE
    DM Classe 1 stérile
    316503
    CE Module D

    CE Module D_en

    Download (1.66M)
    CE 93-42-EEC Gants

    CE 93-42-EEC Gants_en

    Download (269.15k)
    IFU Gants

    IFU Gants_en

    Download (359.39k)

    6 other products in the same category:

    Welcome to API 2000

    In accordance with the 2011-2012 law of December 29, 2011 and in order to access the content of our site, we thank you for confirming that you are indeed a health professional.

    YES